Part Number Hot Search : 
ST230 MMBD7 A178L15 154M0 IDT7280 E180CA 223ML 15005
Product Description
Full Text Search
 

To Download X3AM-115KPASR Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Pre-amplified/3V Excitation/Absolute
Features
. . . . 3V excitation, Battery operation available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span . . . .
X3PM,X3AM Data sheet
Applications
Industrial instrumentation Medical device Barometer, Altimeter Altitude compensation
Part number for ordering
X3AM - 115KP A S R
Rated pressure (Pa) Model X3PM X3AM Pressure type A : Absolute Terminal leads direction (See Outline Diagram) No mark : R :
Terminal leads configuration No mark : DIP(X3PM) S : Surface mount package (X3AM)
Absolute pressure
Pressure type X3PM
X3AM
Model
Package configuration Measurable pressure range (kPa) 15 115
Dual-In-line-Package (DIP) Part number for ordering X3PM-115KPAR
Surface mount package
X3PM-115KPA
X3AM-115KPASR
Specifications
Model/Rated pressure 115KPA Unit Recommended operating conditions Pressure type Absolute pressure Rated pressure 115 Measurable pressure range 15 115 Pressure media Non-corrosive gas only Excitation voltage 3.0 0.15 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation voltage 6 Operating temperature 10 80 Storage temperature 20 100 Operating humidity 30 80 (No dew condensation) Electric performances/characteristics (Excitation voltage Vcc=3.0V constant, Ambient temperature Ta=25 ) Current consumption less than 6 Output impedance less than 10 Source current less than 0.1 Sink current less than 1 Mechanical response time 2 (For the reference) Full scale span voltage 1.5 Offset voltage 0.5 0.075 Full scale span voltage 2.0 0.075 Accuracy 5.0
Note ; Excluding input voltage error.
kPa.abs kPa.abs VDC
VDC
RH mA mA mA msec V V V FS/0 50
1
Pre-amplified/3V Excitation/Absolute
Outline dimensions
X3PM,X3AM Data sheet
Unit : mm
X3PM (Absolute pressure)
12 6 5 4
1. 5
5.5 2.85
8
Pressure port 4 5 6
1
2
3 Labelled faceplate
5
15.24(600mil)
R
14
3
C 5 0.
3
2
1
2.54 2.54
Recommended footprint for PCB
6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands)
0.5
1.2
60
2.8 6.8
15.2
(unit : mm)
Unit : mm
X3PM-R (Absolute pressure)
0.25
12
max.15
5.5 2.85
8
Pressure port 4 5 6
6
5
4
R
1.
5
1
2
3 Labelled faceplate
5
15.24(600mil)
14
3
3
2
1
0.5
2.54 2.54
1.2
60
Recommended footprint for PCB
6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands)
2.8 6.8
15.2 2.54 2.54
(unit : mm)
2
2.54 2.54
0. C 5
Pre-amplified/3V Excitation/Absolute
Outline dimensions
X3PM,X3AM Data sheet
Unit : mm
X3AM
1
2.54 2.54 2 3
7
Pressure port 6 5 7 Index 3 0.15 1 3.5 4 0.8
AX.
10 M
0.8 10.3
15
MA
X.
6 5 4 Labelled faceplate
0.25
Recommended footprint for PCB
1.7 1.4 2.54 2.54 9.4
1
2
3
Land-pads
(unit : mm)
Transfer Function
Vout=Vs (P + ) (Pressure Error Temperature Error Multiplier Vs) Vs=3.0volts Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage. P=Input Pressure(kPa) Model pressure range
050KPG(D) 100KPG(D) 100KPGV 100KPGW(DW) 200KPG(D) 001MPGW(D) 115KPA 0 50kPa 0 100kPa 0 100kPa 0 +100kPa 0 200kPa 0 1MPa 15 115kPa.abs 0.01 0.005 0.005 0.0025 0.0025 0.0025 0.005 0.1667 0.1667 0.1667 0.4667 0.1667 0.1667 0.09167
Temperature Error Multiplier=1
Pressure Error(kPa) 2.5 5.0 5.0 10.0 10.0 50.0 5.0
3
Pre-amplified/3V Excitation/Absolute
Connection diagram
X3PM,X3AM Data sheet
X3PM (Absolute pressure)
Vcc(DC3V) Vcc
Vout Vout GND
Remarks :
C2 C1
1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. 3) 2 and 3 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other.
GND
X3AM
Vcc(DC3V) GND
Vout Vout Vcc C2
Remarks : 1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. 3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other.
C1
GND
Note ; Please read instruction "Notes" before using the sensor. Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 4 E-mail : sensor@fujikura.co.jp


▲Up To Search▲   

 
Price & Availability of X3AM-115KPASR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X